 CYLINDRICAL INDUCTIVE SENSORS IN METAL HOUSING
5 output functions * Amplified in d.c. + a.c. 2 wires * Cable output *
Housing B-2
L5 L1 L2 LED d
Housing G
L1
L5 L2 L3 LED
d
Diameter Nut Size Thickness mm
M18 x 1 SW24 4 35
M30 x 1,5 SW36 5 80
Max tightening torque Nm
Materials:
* Cable: 2 m PVC CEI 20 - 22 II; 90C; 300 V; O.R. * Housing: nickel plated brass * Sensing face: plastic
General Features:
When used in a.c. they work as normally open. When used in d.c. they can work as normally open or normally closed simply by reversing the connection wires. The load can be connected indifferently on the positive or on the negative pole. These sensors put together the four functions of traditional 3 wires amplified sensors: PNP - NO; PNP - NC; NPN - NO; NPN - NC. Besides the a.c. working in many applications they can replace directly electromechanical microswitches. * * * * * * * * * * * * * * * * * * *
Nominal sensing distance ( Sn ) 10%
Technical data:
www..net
Supply voltage (UB): Electrical system frequency: Max ripple: Off-state current (Ir): Minimum operational current (Im): Rated operational current (Ie): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis (H): Degree of protection: LED indication:
Cable conductor cross section: Protected against short-circuit and overload Suppression of initial false impulse Class 2 equipment according to IEC 536 Shock and vibration according to EN60068-2-27 EN60068-2-6 Electromagnetic compatibility (EMC) according to EN61000-6-2/- 4 ORDERING REFERENCES
PNP
NO
I
brown blue Rx + -
10 / 60 Vdc/Vac 40 / 60 Hz 10% 0,6 mA 5 mA 400 mA 4V - 20 / + 70C 10% 2% 10% IP67 yellow = output state blinking red = output short circuit 0,75 mm2
Flush mounting Non flush mounting
Housing
L1
L2
L3
L5
Max switching frequency ( f )
Cable diameter
Body diameter (d)
NPN
NC
I
blue brown Rx + -
A.C.
NC NO
+ -
NO
I
brown Rx blue + -
I
blue
mm
mm
mm
mm
mm
mm
Hz
mm
Rx brown
I
brown blue Rx
B-2 B-2 G G
* * * *
10 15
50 40 50 35
10 10
50 50 60 60
5 5 5 5
M18 x 1 M18 x 1
800 400
5 8 10 15
DX18/4A5XKS DX18/5A5XKS DX30/465XKS DX30/565XKS
M30 x 1,5 600 M30 x 1,5 300
BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com
A-51
CYLINDRICAL INDUCTIVE SENSORS IN METAL HOUSING
* 5 output functions * Amplified in d.c. + a.c. 2 wires * Connector output M12 x 1
Housing I-12
L5 L1 d 4 x LED L2 L3 L4
2
M12 x 1
3 4
1
Housing I-2
L5 L1 L2 L3 L4
2
d 4 x LED
M12 x 1
3 4
1
Diameter Nut Size Thickness mm
M18 x 1 SW24 4 35
M30 x 1,5 SW36 5 80
Max tightening torque Nm
Materials:
* Housing: * Sensing face:
nickel plated brass plastic
General Features:
When used in a.c. they work as normally open. When used in d.c. they can work as normally open or normally closed simply by reversing the connection wires. The load can be connected indifferently on the positive or on the negative pole. These sensors put together the four functions of traditional 3 wires amplified sensors besides the a.c. working. In many applications they can replace directly electromechanical microswitches. * * * * * * * * * * * * * * * * *
Technical data:
www..net
Supply voltage (UB): 10 / 60 Vdc/Vac Electrical system frequency: 40 / 60 Hz Max ripple: 10% 0,6 mA Off-state current (Ir): 5 mA Minimum operational current (Im): 4V Voltage drop (Ud): Temperature range: - 20 / + 70C 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Protected against short-circuit and overload Suppression of initial false impulse Class 2 equipment according to IEC 536 Shock and vibration according to EN60068-2-27 EN60068-2-6 Electromagnetic compatibility (EMC) according to EN60947-5-2
Nominal sensing distance ( Sn ) 10%
Flush mounting Non flush mounting
Rated operational current ( Ie )
ORDERING REFERENCES
PNP
NO
I
1 brown 4 blue Rx + ---
Max switching frequency ( f )
Female connector
Housing
L1
L2
L3
L4
L5
Body diameter (d)
NPN
NO
I
1 brown Rx 4 blue + ---
A.C.
NO
I
1 brown 4 blue
NC
I
4 blue 1 brown Rx + ---
NC
I
4 blue Rx 1 brown + ---
mm
mm
mm
mm
mm
n
mm
Hz
mA
mm
I -12 I -12 I-2 I-2
* * * *
10 15
50 50 65 50
19 19 17 17
8 8 8 8
77 87 90 90
6 - 8B -10 6 - 8B -10 6 - 8B -10 6 - 8B -10
M18 x 1 M18 x 1
800 400 400 400
5 8 10 15
DX18/435XKS DX18/535XKS DX30/435XKS DX30/535XKS
M30 x 1,5 600 400 M30 x 1,5 300 400
A-52
BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com
CYLINDRICAL INDUCTIVE SENSORS IN METAL HOUSING
Voltage 10 / 50 V * Amplified in d.c. + a.c. 2 wires * Cable output *
Housing B-6
L1 d LED L5 L2 L3
Housing B-3
L1 d L5 L2 L3
LED
Housing C
L1
L5 L2 L3 LED
d
Housing G
L1
L5 L2 L3 LED
General Features:
d
These sensors are able to work with either direct or alternate current. Voltage drop and residual current are very low. They are not polarized and the load can be connected on both the leads. In many applications they can used to replace mechanical microswitches. * * * * * * * * * * * * * * * *
Technical data:
Diameter Nut Size Thickness mm
M8 x 1 SW13 4 10
M12 x 1 SW17 4 15
M18 x 1 SW24 4 35
M30 x 1,5 SW36 5 80
Max tightening torque Nm
Materials:
* * * *
Cable: 2 m PVC CEI 20 - 22 II; 90C; 300 V; O.R. Housing 8 mm: stainless steel Housing 12 - 18 - 30 mm: nickel plated brass Sensing face: plastic
www..net
10 / 50 Vdc/Vac 40 / 60 Hz 1 mA 5 mA 5V - 25 / + 70C 10% 2% 10% IP67 yellow LED 0,35 mm2 on 8 and 12 mm 0,50 mm2 on 18 mm 0,75 mm2 on 30 mm Protected against short-circuit and overload (versions with letter K) Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 Shock and vibration resistance according to EN60068-2-27 EN60068-2-6
Nominal sensing distance ( Sn ) 10% Rated operational current ( Ie ) Max switching frequency ( f ) in a.c.
Supply voltage (UB): Electrical system frequency: Off-state current (Ir): Minimum operational current (Im): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis (H): Degree of protection: Switch status indicator: Cable conductor cross section:
Flush mounting Non flush mounting
Max switching frequency ( f ) in d.c.
Cable diameter
Housing
L1
L2
L3
L4
L5
Body diameter (d)
ORDERING REFERENCES
NO
I
black black
NC
I
black black
mm
mm
mm
mm
mm
mm
mm
Hz
Hz
mA
mm
B-6 B-6 B-3 B-3 C C G G
* * * * * * * *
5 7 10 15
40 35 43 36 58 48 50 35
5 5 7 7 12 12 10 10
-
45 45 50 50 70 70 60 60
4 4 4 4 5 5 6 6
M8 x 1 M8 x 1 M12 x 1 M12 x 1 M18 x 1 M18 x 1 M30 x 1,5 M30 x 1,5
1000 800 800 600 800 400 400 200
25 25 25 25 25 25 25 25
100 1,5 100 2,5 100 100 200 200 200 200 2 4 5 8 10 15
AXM8/4600S AXM8/5600S AXM12/4600KS AXM12/5600KS AXM18/4600KS AXM18/5600KS AXM30/4600KS AXM30/5600KS
AXM8/4610S AXM8/5610S AXM12/4610KS AXM12/5610KS AXM18/4610KS AXM18/5610KS AXM30/4610KS AXM30/5610KS
BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com
A-53
CYLINDRICAL INDUCTIVE SENSORS IN METAL HOUSING
* Supply 10 / 50 V * Amplified in d.c. + a.c. * Connector output M12 x 1
Housing I-11
L5 L1 d 4 x LED L2 L3 L4
2
M12 x 1
3 4
1
Housing I-7
L1 d L2
L5 L3 L4
2
M12 x 1 4 x LED
3 4
1
Housing I-12
L5 L1 d 4 x LED L2 L3 L4
2
M12 x 1
3 4
1
Housing I-2
L5 L1 L2 L3 L4
2
General Features:
1
d 4 x LED
Diameter Nut Size Thickness mm M8 x 1 SW13 4 10 M12 x 1 SW17 4 15
M12 x 1
3 4
These sensors are able to work with either direct or alternate current. Voltage drop and residual current are very low. They are not polarized and the load can be connected on both the leads. In many applications they can used to replace mechanical microswitches. * * * * * * * * * * * * * * *
M18 x 1 SW24 4 35
M30 x 1,5 SW36 5 80
Technical data:
Max tightening torque Nm
Materials:
* Housing 8 mm: * Housing 12 - 18 - 30 mm: * Sensing face:
www..net
stainless steel nickel plated brass plastic
Supply voltage (UB): 10 / 50 Vdc/Vac Electrical system frequency: 40 / 60 Hz 1 mA Off-state current (Ir): 5 mA Minimum operational current (Im): 5V Voltage drop (Ud): Temperature range: - 25 / + 70C 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Protected against short-circuit and overload (versions with letter K) Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 Shock and vibration resistance according to EN60068-2-27 EN60068-2-6
Nominal sensing distance ( Sn ) 10% Rated operational current ( Ie ) Max switching frequency ( f ) in a.c.
Flush mounting Non flush mounting
Max switching frequency ( f ) in d.c.
Female connector
Housing
L1
L2
L3
L4
L5
Body diameter (d)
ORDERING REFERENCES
NO
I
3 blue 4 black
NC
I
1 brown 2 white
mm
mm
mm
mm
mm
n
mm
Hz
Hz
mA
mm
I - 11 I - 11 I-7 I-7 I - 12 I - 12 I-2 I-2
* * * * * * * *
5 7 10 15
40 35 43 36 50 50 65 50
12 12 15 15 19 19 17 17
8 8 8 8 8 8 8 8
60 60 66 66 77 87 90 90
6 - 8B -10 6 - 8B -10
M8 x 1 M8 x 1
1000 800 800 600 800 400
25 25 25 25 25 25 25 25
100 1,5 100 2,5 100 100 200 200 200 200 2 4 5 8 10 15
AXM8/4300S AXM8/5300S AXM12/4300KS AXM12/5300KS AXM18/4300KS AXM18/5300KS AXM30/4300KS AXM30/5300KS
AXM8/4310S AXM8/5310S AXM12/4310KS AXM12/5310KS AXM18/4310KS AXM18/5310KS AXM30/4310KS AXM30/5310KS
6 - 8B -10 M12 x 1 6 - 8B -10 M12 x 1 6 - 8B -10 M18 x 1 6 - 8B -10 M18 x 1
6 - 8B -10 M30 x 1,5 400 6 - 8B -10 M30 x 1,5 200
A-54
BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com
CYLINDRICAL INDUCTIVE SENSORS IN METAL HOUSING
Voltage 20 / 240 V * Amplified in d.c. + a.c. 2 wires * Cable output *
Housing B-6
L1 d LED L5 L2 L3
Housing B-3
L1 d L5 L2 L3
LED
Housing B-2
L1
L5 L2 LED
d
General Features:
Housing G
L1 L5 L2 L3 LED d
These sensors are able to work with either direct or alternate current. Voltage drop and residual current are very low. They are not polarized and the load can be connected on both the leads. In many applications they can used to replace mechanical microswitches. * * * * * * * * * * * * * * * * * *
Technical data:
Diameter Nut Size Thickness mm
M8 x 1 SW13 4 10
M12 x 1 SW17 4 15
M18 x 1 SW24 4 35
M30 x 1,5 SW36 5 80
Max tightening torque Nm
Materials:
* * * *
Cable: 2 m PVC CEI 20 - 22 II; 90C; 300 V; O.R. Housing 8 mm: stainless steel Housing 12 -18 - 30 mm: nickel plated brass Sensing face: plastic
www..net
20 / 240 Vdc/Vac 40 / 60 Hz 1 mA 1,5 mA 5 mA 5V - 25 / + 70C 10% 2% 10% IP67 yellow LED 0,35 mm2 on 8 and 12 mm 0,50 mm2 on 18 mm 0,75 mm2 on 30 mm Protected against short-circuit and overload (versions with letter K) Suppression of initial false impulse Class 2 equipment according to IEC 536 Shock and vibration according to EN60068-2-27 EN60068-2-6 Electromagnetic compatibility (EMC) according to EN60947-5-2
Nominal sensing distance ( Sn ) 10% Rated operational current ( Ie ) Max switching frequency ( f ) in a.c.
Supply voltage (UB): Electrical system frequency: Off-state current (Ir) at 24 V: Off-state current (Ir) at 220 V: Minimum operational current (Im): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis (H): Degree of protection: Switch status indicator: Cable conductor cross section:
Flush mounting Non flush mounting
Max switching frequency ( f ) in d.c.
Cable diameter
Housing
L1
L2
L3
L4
L5
Body diameter (d)
ORDERING REFERENCES
NO
I
black black
NC
I
black black
mm
mm
mm
mm
mm
mm
mm
Hz
Hz
mA
mm
B-6 B-6 B-3 B-3 B-2 B-2 G G
* * * * * * * *
5 7 10 15
40 35 43 36 50 40 50 35
5 5 7 7 10 10
-
45 45 50 50 50 50 60 60
3,5 3,5 4 4 5 5 6 6
M8 x 1 M8 x 1 M12 x 1 M12 x 1 M18 x 1 M18 x 1 M30 x 1,5 M30 x 1,5
1000 800 800 600 800 400 400 200
25 25 25 25 25 25 25 25
100 1,5 100 2,5 100 100 200 200 200 200 2 4 5 8 10 15
AX8/4609S AX8/5609S AX12/4609KS AX12/5609KS AX18/4A09KS AX18/5A09KS AX30/4609KS AX30/5609KS
AX8/4619S AX8/5619S AX12/4619KS AX12/5619KS AX18/4A19KS AX18/5A19KS AX30/4619KS AX30/5619KS
BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com
A-55
CYLINDRICAL INDUCTIVE SENSORS IN METAL HOUSING
* Voltage 20 / 240 V * Amplified in d.c. + a.c. * Connector output M12 x 1
Housing A-7
L5 L1 d LED L2 L3 L4
1
M12 x 1
2
3
Housing A-1
L5 L1 d LED L2 L3 L4
1
M12 x 1
2
3
Housing A-2
L5 L1 L2 L3 L4
1
d
M12 x 1 LED
2
3
General Features:
These sensors are able to work with either direct or alternate current. Voltage drop and residual current are very low. They are not polarized and the load can be connected on both the leads. In many applications they can used to replace mechanical microswitches. * * * * * * * * * * * * * * * * *
Diameter Nut Size Thickness mm
M12x 1 SW17 4 15
M18 x 1 SW24 4 35
M30 x 1,5 SW36 5 80
Technical data:
Max tightening torque Nm
Materials:
* Housing: * Sensing face:
www..net
nickel plated brass plastic
Supply voltage (UB): 20 / 240 Vdc/Vac Electrical system frequency: 40 / 60 Hz Off-state current (Ir) at 24 V: 1 mA Off-state current (Ir) at 220 V: 1,5 mA 5 mA Minimum operational current (Im): 5V Voltage drop (Ud): Temperature range: - 25 / + 70C 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Protected against short-circuit and overload Suppression of initial false impulse Class 2 equipment according to IEC 536 Shock and vibration according to EN60068-2-27 EN60068-2-6 Electromagnetic compatibility (EMC) according to EN60947-5-2
Nominal sensing distance ( Sn ) 10% Rated operational current ( Ie ) Max switching frequency ( f ) in a.c.
Flush mounting Non flush mounting
Max switching frequency ( f ) in d.c.
Female connector
Housing
L1
L2
L3
L4
L5
Body diameter (d)
ORDERING REFERENCES
NO
I
3 blue 2 brown 1 yellow-green
NC
I
3 blue 2 brown 1 yellow-green
mm
mm
mm
mm
mm
n
mm
Hz
Hz
mA
mm
A-7 A-7 A-1 A-1 A-2 A-2
* * * * * *
7 10 15
43 36 50 50 65 50
15 15 19 19 17 17
8 8 8 8 8 8
66 66 77 87 90 90
17-18 17-18 17-18 17-18 17-18 17-18
M12 x 1 M12 x 1 M18 x 1 M18 x 1 M30 x 1,5 M30 x 1,5
800 600 800 400 400 200
25 25 25 25 25 25
100 100 200 200 200 200
2 4 5 8 10 15
AX12/4009KS AX12/5009KS AX18/4009KS AX18/5009KS AX30/4009KS AX30/5009KS
AX12/4019KS AX12/5019KS AX18/4019KS AX18/5019KS AX30/4019KS AX30/5019KS
A-56
BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com


▲Up To Search▲   

 
Price & Availability of AX124009KS

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X